What UL 94 V-0 means — and what it does not
UL 94 is a small-scale flammability test for plastics. In the vertical test, bars are clamped upright, a 20 mm flame is applied twice for 10 s, and dry cotton below catches any drips. V-0 is the strictest vertical class: each bar stops flaming within 10 s, the five bars together burn no more than 50 s, nothing burns to the clamp and no drip ignites the cotton. V-1 and V-2 allow 30 s per bar; V-2 also allows flaming drips.
The rating belongs to a material at a stated thickness, often 1.5 mm, and in a stated color. UL lists recognized grades in its iQ database, summarized on the grade’s “Yellow Card”. A resin that passes at 1.5 mm can fail when thinner. Ask whether a filament’s claim covers the base resin or printed specimens, and which lab tested it.
A printed part is not automatically V-0. Thin walls, sparse infill, air gaps between roads and build orientation all change how it burns. Aircraft cabins (FAR 25.853) and rail vehicles (EN 45545-2) use their own, different tests; a UL 94 rating does not show compliance with either.
Halogen-free grades avoid brominated additives, typically relying on phosphorus-based chemistry.
Typical properties
| Property | Typical range | Test method |
|---|---|---|
| Flammability | V-0, usually at 1.5 mm; some grades also at 3 mm | UL 94 / IEC 60695-11-10 |
| Glow-wire flammability index | 960 °C at 1.5 mm on some grades | IEC 60695-2-12 |
| Tensile strength (yield) | 50–60 MPa | ISO 527 |
| Tensile modulus | 2.6–2.9 GPa | ISO 527 |
| Vicat softening | 104–110 °C | ISO 306 |
| Heat deflection, 1.8 MPa | ≈ 90 °C | ISO 75 |
| Density | 1.17–1.20 g/cm³ | ISO 1183 |
Typical published values across manufacturers, measured on test specimens; check your spool’s datasheet. Printed parts are usually weaker between layers (Z) than along them (XY).
Typical print settings
| Nozzle temperature | 240–285 °C |
|---|---|
| Build plate | 90–120 °C |
| Chamber | Enclosed; heated recommended (Epitum: up to 90 °C) |
| Print speed | 30–60 mm/s for fire-critical walls |
| Part cooling | 0–25% |
| Drying | 75–80 °C · 4–6 h |
| Nozzle | Standard, ≥ 0.4 mm |
Starting point compiled from manufacturers’ recommendations — fine-tune with the Printoformer material profile for your spool, nozzle and part geometry.
Start mid-range and favor fusion over speed: a dense, well-bonded wall is what a flame test sees.
Which Epitum: JL or L
The Epitum L fits single-material runs of enclosures, covers and brackets; the 360 × 360 × 610 mm volume takes large housings in one piece, and the heated chamber, up to 90 °C, limits warping on wide flat panels. Choose the Epitum JL for housings with internal bosses or cable channels that need soluble support. Remove all support residue: it is not part of the rated material.
Applications
- Electrical enclosures, junction boxes and battery-pack covers
- Connector housings, fuse and relay covers
- Low-volume housings that must pass a flammability check
- Prototypes of molded flame-retardant PC/ABS parts
Troubleshooting and tips
- Design to the rated thickness. Keep fire-critical walls at or above the thickness on the datasheet and print them solid — extra perimeters, 100% infill.
- Weak layers: raise the chamber and nozzle temperature and keep the fan low before slowing down.
- Warping on flat panels: close the chamber, add a brim and round sharp corners.
- Bubbles or streaks: dry the spool; PC blends absorb moisture.
- Qualify the part. If the end product needs a listing, test printed parts in their final geometry.
Available from MG World Tech: PC ABS V0, 1 kg spool, $68.71. Order or request a quote →
Frequently asked questions
Is a part printed from UL94 V0 filament V-0 rated?
Not automatically. The rating applies to the material at the thickness it was tested at. Wall thickness, infill, voids and orientation change fire behavior, so if your product needs a listing, test the printed part.
What does UL 94 V-0 mean?
In the vertical burn test each specimen self-extinguishes within 10 s of each flame application, five specimens burn 50 s or less in total, and no flaming drips ignite the cotton below.
What wall thickness should flame-retardant prints have?
At least the thickness stated with the rating — commonly 1.5 mm — printed solid. Thicker walls generally behave better in a flame test than thin ones.
Does UL 94 V-0 meet FAR 25.853 or EN 45545?
No. Aircraft interiors (FAR 25.853) and railway vehicles (EN 45545-2) have their own test methods and limits. A UL 94 rating is a separate classification and does not demonstrate compliance with either.